AS Control (o/n A26) unlocks all AS modules in Clarity software.
The direct control of Autosamplers generally includes the control
of the injections /washing.
This control is implemented in the Sequence table. Advanced options
for selected headspece autosamplers are also available. The scope
of control for a specific autosampler can be found in the description
of the respective control module.
|
| |
Available AS Control modules:
|
|
Agilent 7673 |
The
Agilent 7673 Control module enables direct control of the Agilent
automatic liquid sampler (ALS) for GC. It provides a complete control
of the Agilent 7673A, 7673 II and 7683 ALS.
The control of the ALS together with the control of GCs enables Clarity
to provide integrated instrument control and to ensure complete automation
for laboratories. The chromatography station with the AS control module
provides the user with access to all parameters of an injection directly
from a computer and allows the user to determine the order of individual
vials within sequences.
Specific method can be selected for each sample in a given sequence.
The method includes the AS control parameters, parameters of data
acquisition, integration and calculation. Straight from the software
you can plan and edit the sequence table. For HP18594 A, B controllers
an RS232 interface card is necessary. DataApex supplies this card
(Order no. IHP76)
G1512A controller already has the RS232 interface circuits. |
| |
| |
|
CTC Combi PAL LC |
The
CTC Combi PAL LC Control module enables direct control of the CTC
Combi PAL LC autosampler over serial line. Direct control means that
the autosampler can completely controlled from the Clarity environment.
Instrument method controlling the sample preparation conditions will
be saved in the measured chromatograms The chromatography station
with the AS control module provides the user with access to all parameters
of an injection directly from a computer and allows the user to determine
the order of individual vials within sequences. Specific method can
be selected for each sample in a given sequence. The method includes
AS control parameters, parameters of data acquisition, integration
and calculation. Straight from the software you can plan and edit
the sequence table. |
| |
| |
| |
|
Ecom AS54 |
The
Ecom AS54 Control enables to control the Ecom AS54 autosampler. |
| |
| |
| |
|
HTA 200H |
The
HT200H Control module enables direct control of the HT200H Headspace
autosampler over serial line. Direct control means that the autosampler
can completely controlled from the Clarity environment. Instrument
method controlling the sample preparation conditions will be saved
in the measured chromatograms The chromatography station with the
AS control module provides the user with access to all parameters
of an injection directly from a computer and allows the user to determine
the order of individual vials within sequences. Specific method can
be selected for each sample in a given sequence. The method includes
AS control parameters, parameters of data acquisition, integration
and calculation. Straight from the software you can plan and edit
the sequence table. |
| |
| |
| |
|
HTA 300A/300L |
The
HTA AS300A/300L control module enables direct control of the HTA over
serial line. Direct control means that the autosampler can completely
controlled from the Clarity environment. Instrument method controlling
for example the vials and further device specific functions (e.g.
washing) will be saved in the measured chromatograms.
The chromatography station with the AS control module provides the
user with direct computer access to all injection parameters and allows
to determine the order of individual vials within sequences. A specific
method can be selected for each sample in a given sequence. The method
includes AS control parameters, parameters of data acquisition, integration
and calculation. Straight from the software the user can plan and
edit the sequence table. |
| |
| |
| |
|
Shimadzu AOC20 |
The
Shimadzu AOC20 Control module enables direct control of the Shimadzu
AOC20 autosampler over serial line. Direct control means that the
autosampler can completely controlled from the Clarity environment.
Instrument method controlling the sample preparation conditions will
be saved in the measured chromatograms The chromatography station
with the AS control module provides the user with access to all parameters
of an injection directly from a computer and allows the user to determine
the order of individual vials within sequences. Specific method can
be selected for each sample in a given sequence. The method includes
AS control parameters, parameters of data acquisition, integration
and calculation. Straight from the software you can plan and edit
the sequence table. |
| |
| |
| |
|
Spark-Holland Marathon |
The
SPH Marathon control module enables direct control of the Spark Marathon
Basic, Basic Plus, and XT Marathon autosamplers. The control is performed
over the serial line.
Direct control means that the autosampler can be completely controlled
from the Clarity environment. Instrument method controlling the sample
preparation conditions will be saved in the measured chromatograms.
It is recommended to check the user manual of the autosampler for
its operating principles and restrictions. The chromatography station
with the AS control module provides the user with access to all parameters
of an injection directly from a computer and allows the user to determine
the order of individual vials within sequences. Specific method can
be selected for each sample in a given sequence. The method includes
AS control parameters, parameters of data acquisition, integration
and calculation. Straight from the software you can plan and edit
the sequence table. |
| |
| |
| |
|
Spark-Holland Midas |
The
SPH Midas control module enables direct control of the Spark Midas
autosampler. The control is performed over the serial line.
Direct control means that the autosampler can be completely controlled
from the Clarity environment. Instrument method controlling the sample
preparation conditions will be saved in the measured chromatograms.
It is recommended to check the user manual of the autosampler for
its operating principles and restrictions. The chromatography station
with the AS control module provides the user with access to all parameters
of an injection directly from a computer and allows the user to determine
the order of individual vials within sequences. Specific method can
be selected for each sample in a given sequence. The method includes
AS control parameters, parameters of data acquisition, integration
and calculation. Straight from the software you can plan and edit
the sequence table. |
| |
| |