Main Features
Data Acquisition
Simultaneous data acquisition from up to four four-detector chromatographs
(4×4 configuration), detector delay correction for multidetector
measurement. Data Processing: The same chromatograms can be evaluated
in both standard and GPC modes, multiple peaks and multiple signals
are processed in one chromatogram.
GPC Integration
Separate integration tables for GPC and standard evaluation are
used. There are extensive possibilities for modifying chromatograms.
The chromatogram integration can be changed by entering global parameters
or interactively, through the direct graphical modification of the
baseline.
GPC Calibrations
Narrow, Broad, Broad on Narrow standard calibration methods combined
with Flow Rate correction and Universal calibration. Manual calibration
or automated recalibration from sequence. Multiple Broad standards
can be used.
GPC Calculations
Polynomial (n= 1-5) curve fits (independent for signals), Mp, Mn,
Mw , Mv , Mz, Mz+1 molecular weight averages and polydispersity.
Graphs
Molecular weight distribution graphs. Overlay: Simultaneously displays
a virtually unlimited number of chromatograms. Overlay of dW/d logM
vs log M and cumulative height graphs.
Export
Slice Table results, graphs, result and summary tables.
User Calculations
User can define custom calculations in the Result and Summary tables.
Using the integrated editor you can create your own columns from
the original columns and individual mathematical functions.
GPC Results Table
Displays molecular weight averages together with peak details for
active signal. Multiple peaks can be evaluated from one chromatogram.
GPC Summary Result Tables
Displays and prints selected results from all simultaneously displayed
chromatograms. Postrun: Automatically displays, prints, exports
and starts other programs after the completion of a measurement.
Batch
Automatically batch processes, displays, exports or prints any
number of chromatograms.
Reports
User selectable report sections and WYSIWYG formating of Graphs
and Tables
GPC Screenshots
Instrument - GPC mode
The GPC Extension is an optional extension for the Clarity Chromatography
Station (from version 2.3) and Clarity Offline. GPC mode can be
selected for any Clarity Instrument within a station. The same chromatograms
can be evaluated in both standard and GPC modes.
Chromatogram - Broad on Narrow
Molecular weight distribution graphs. Overlay: Simultaneously displays
a virtually unlimited number of chromatograms. Overlay of dW/d logM
vs log M and cumulative height graphs.
Chromatogram - MW Distribution
K & Alpha
GPC Sequence
Report Setup
User selectable report sections and WYSIWYG formating of Graphs
and Tables.
|